Solid-State Smartspot Indicator Time-Delay for Motor Starting and Transformer Inrush Currents Without Nuisance Opening 300ka Interrupting Rating, Self-Certified (Ul Witnessed) Extremely Current-Limiting for Low Peak Let-Thru Current Easy 2-to-1 Selecti
Bolt Head Is Combination Slot and Hex Head for Flexibility of Attachment
View:
Active Filters :
- Special Features: Bolt Head Is Combination Slot and Hex Head for Flexibility of Attachment Solid-State Smartspot Indicator Time-Delay for Motor Starting and Transformer Inrush Currents Without Nuisance Opening 300ka Interrupting Rating, Self-Certified (Ul Witnessed) Extremely Current-Limiting for Low Peak Let-Thru Current Easy 2-to-1 Selecti
Part #:FRZA2D50R
- A2D50R|AzD50R|A2D5oR|Mersen A2D50R|Mersen AzD50R|Mersen A2D5oR|MERSEN FERRAZ A2D50R|MERSEN FERRAZ AzD50R|MERSEN FERRAZ A2D5oR|Mersin A2D50R|Mersin AzD50R|Mersin A2D5oR|Merson A2D50R|Merson AzD50R|Merson A2D5oR|MERS A2D50R|MERS AzD50R|MERS A2D5oR|Ferazz A2D50R|Ferazz AzD50R|Ferazz A2D5oR|Mersan A2D50R|Mersan AzD50R|Mersan A2D5oR|00782001990930|0007820|78200199093|99093|"250V 50A RK1 TD FUSE|Amp-Trap 2000 SmartSpot time-delay A2D-R fuses provide IEC Type 2 ""no damage"" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A2D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A2D-R fuses can be used to replace 250V Class H, K or RK5 ":
$
58.54
Qty:
Part #:FRZA2D125R
- 00782001991050|0782001|782001991050|78200199105|99105|A2D125R|250V 125A RK1 TD FUSE|FERRAZ A2D125R|Ferraz Shawmut A2D125R|GOULD A2D125R|Mersan A2D125R|MERSEN A2D125R|MERSEN/FERRAZ SHAWMUT A2D125R|Mersin A2D125R|Merson A2D125R|ShawmutFuses A2D125R:
$
253.49
Qty:
Part #:FRZA2D225R
- 00782001991111|0782001|782001991111|78200199111|99111|A2D225R|250V 225A RK1 TD FUSE|FERRAZ A2D225R|Ferraz Shawmut A2D225R|GOULD A2D225R|Mersan A2D225R|MERSEN A2D225R|MERSEN/FERRAZ SHAWMUT A2D225R|Mersin A2D225R|Merson A2D225R|ShawmutFuses A2D225R:
$
479.37
Qty:
Part #:FRZA2D600R
- A2D600R|AzD600R|A2D6ooR|Mersen A2D600R|Mersen AzD600R|Mersen A2D6ooR|MERSEN FERRAZ A2D600R|MERSEN FERRAZ AzD600R|MERSEN FERRAZ A2D6ooR|Mersin A2D600R|Mersin AzD600R|Mersin A2D6ooR|Merson A2D600R|Merson AzD600R|Merson A2D6ooR|MERS A2D600R|MERS AzD600R|MERS A2D6ooR|Ferazz A2D600R|Ferazz AzD600R|Ferazz A2D6ooR|Mersan A2D600R|Mersan AzD600R|Mersan A2D6ooR|"250V 600A RK1 TD FUSE|Amp-Trap 2000 SmartSpot time-delay A2D-R fuses provide IEC Type 2 ""no damage"" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A2D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A2D-R fuses can be used to replace 250V Class H, K or RK5 "|00782001991203|0007820|78200199120|99120:
$
746.57
Qty:
Displaying: 25 - 28 of 28 Matching Items