Mersen Fuse Reducers Allow the Use of Lower Rated Fuses in Existing Equipment Having Clips With Higher Ampere Ratings. the Use of Closer Rated Time-Delay Fuses Can Improve Circuit Protection. for Example, Renewable or One-Time Fuses Feeding a Motor Can B
FUSES & ACCESSORIES
View:
Active Filters :
- Sub Cat 1: FUSES & ACCESSORIES
- Application: Mersen Fuse Reducers Allow the Use of Lower Rated Fuses in Existing Equipment Having Clips With Higher Ampere Ratings. the Use of Closer Rated Time-Delay Fuses Can Improve Circuit Protection. for Example, Renewable or One-Time Fuses Feeding a Motor Can B Street Lighting Parking Lot Lighting Traffic Signaling Sports Lighting Boats and Marinas Humid/corrosive Environments
Part #:FRZFEC1111
- 00782001301118|0007820|78200130111|30111|CC FH INLINE 1P 11-11|Fuse Block 600VAC 600VDC Class CC 30A 1-Pole 11-11 Crimp|Fuse Block 600VAC 600VDC Class CC 30A 1-Pole 11-11 Crimp|Mersen FEC-11-11|Mersen FEC 11 11|Mersen FEC1111|Mersen FEC-ll-ll|MERSEN FERRAZ FEC-11-11|MERSEN FERRAZ FEC 11 11|MERSEN FERRAZ FEC1111|MERSEN FERRAZ FEC-ll-ll|Mersin FEC-11-11|Mersin FEC 11 11|Mersin FEC1111|Mersin FEC-ll-ll|Merson FEC-11-11|Merson FEC 11 11|Merson FEC1111|Merson FEC-ll-ll|MERS FEC-11-11|MERS FEC 11 11|MERS FEC1111|MERS FEC-ll-ll|Ferazz FEC-11-11|Ferazz FEC 11 11|Ferazz FEC1111|Ferazz FEC-ll-ll|Mersan FEC-11-11|Mersan FEC 11 11|Mersan FEC1111|Mersan FEC-ll-ll|FEC-11-11|FEC 11 11|FEC1111|FEC-ll-ll:
$
73.77
Qty:
Part #:FRZ632
- 00782001752231|0007820|78200175223|75223|"FUSE REDUCER 60-30A 250V|Mersen fuse reducers allow the use of lower rated fuses in existing equipment having clips with higher ampere ratings. The use of closer rated time-delay fuses can improve circuit protection. For example, renewable or one-time fuses feeding a motor can be replaced with fuses sized closer to the motor nameplate current. Non-rejection reducers will allow Class H, K or R fuses to fit Class H or K clips. Rejection-type reducers will allow only Class R fuses to fit Class R"|632|63z|Mersen 632|Mersen 63z|MERSEN FERRAZ 632|MERSEN FERRAZ 63z|Mersin 632|Mersin 63z|Merson 632|Merson 63z|MERS 632|MERS 63z|Ferazz 632|Ferazz 63z|Mersan 632|Mersan 63z:
$
30.09
Qty:
Part #:FRZ162
- FUSE REDUCER 100-60A 250V|Mersen fuse reducers allow the use of lower rated fuses in existing equipment having clips with higher ampere ratings. The use of closer rated time-delay fuses can improve circuit protection. For example, renewable or one-time fuses feeding a motor can be replaced with fuses sized closer to the motor nameplate current. Non-rejection reducers will allow Class H, K or R fuses to fit Class H or K clips. Rejection-type reducers will allow only Class R fuses to fit Class R|00782001752255|0007820|78200175225|75225|Mersen 162|Mersen 16z|Mersen l62|MERSEN FERRAZ 162|MERSEN FERRAZ 16z|MERSEN FERRAZ l62|Mersin 162|Mersin 16z|Mersin l62|Merson 162|Merson 16z|Merson l62|MERS 162|MERS 16z|MERS l62|Ferazz 162|Ferazz 16z|Ferazz l62|Mersan 162|Mersan 16z|Mersan l62|162|16z|l62:
$
46.83
Qty:
Part #:FRZ636
- Mersen 636|MERSEN FERRAZ 636|Mersin 636|Merson 636|MERS 636|Ferazz 636|Mersan 636|636|"FUSE REDUCER 60-30A 600V|Mersen fuse reducers allow the use of lower rated fuses in existing equipment having clips with higher ampere ratings. The use of closer rated time-delay fuses can improve circuit protection. For example, renewable or one-time fuses feeding a motor can be replaced with fuses sized closer to the motor nameplate current. Non-rejection reducers will allow Class H, K or R fuses to fit Class H or K clips. Rejection-type reducers will allow only Class R fuses to fit Class R"|00782001752330|0007820|78200175233|75233:
$
35.34
Qty:
Part #:FRZ166
- 00782001752347|0007820|78200175234|75234|"FUSE REDUCER 100-60A 600V|Mersen fuse reducers allow the use of lower rated fuses in existing equipment having clips with higher ampere ratings. The use of closer rated time-delay fuses can improve circuit protection. For example, renewable or one-time fuses feeding a motor can be replaced with fuses sized closer to the motor nameplate current. Non-rejection reducers will allow Class H, K or R fuses to fit Class H or K clips. Rejection-type reducers will allow only Class R fuses to fit Class R"|Mersen 166|Mersen l66|MERSEN FERRAZ 166|MERSEN FERRAZ l66|Mersin 166|Mersin l66|Merson 166|Merson l66|MERS 166|MERS l66|Ferazz 166|Ferazz l66|Mersan 166|Mersan l66|166|l66:
$
79.60
Qty:
Part #:FRZR262
- 60-200A R FUSE REDUCER PR|Mersen fuse reducers allow the use of lower rated fuses in existing equipment having clips with higher ampere ratings. The use of closer rated time-delay fuses can improve circuit protection. For example, renewable or one-time fuses feeding a motor can be replaced with fuses sized closer to the motor nameplate current. Non-rejection reducers will allow Class H, K or R fuses to fit Class H or K clips. Rejection-type reducers will allow only Class R fuses to fit Class R|00782001752392|0007820|78200175239|75239|R262|Rz6z|Mersen R262|Mersen Rz6z|MERSEN FERRAZ R262|MERSEN FERRAZ Rz6z|Mersin R262|Mersin Rz6z|Merson R262|Merson Rz6z|MERS R262|MERS Rz6z|Ferazz R262|Ferazz Rz6z|Mersan R262|Mersan Rz6z:
$
182.49
Qty:
Displaying: 1 - 6 of 6 Matching Items